Item # |
Method of Detection |
Ranges Available |
Resolution |
Alarms |
|---|---|---|---|---|
| 975A | N/A Electrochemical sensor for O2 NDIR infrared detector for CO, CO2 and CH4 Thermal conductivity cell for H2 | N/A 0-10.0%, 0-50.0%, 0-100.0% CO 0-10.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-5.0%, 0-50.0%, 0-100.0% H2 0-50.0%, 0-100.0% CH4 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972A | N/A NDIR infrared detector for CO and CO2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 974B | N/A NDIR infrared detector for CO and CO2 Paramagnetic sensor for O2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 974A | N/A NDIR infrared detector for CO, CO2 and CH4 Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 974C | N/A NDIR infrared detector for CO, CO2 and CH4 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 974D | N/A NDIR infrared detector for CO and CH4 Paramagnetic sensor for O2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 973A | N/A NDIR infrared detector for CO, CO2 and CH4 | N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 973B | N/A NDIR infrared detector for CO and CO2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 973C | N/A NDIR infrared detector for CO and CO2 Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 973D | N/A NDIR infrared detector for CO and CH4 Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972E | N/A Paramagnetic sensor for O2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972B | N/A NDIR infrared detector for CO Thermal conductivity cell for H2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972C | N/A NDIR infrared detector for CO Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972D | N/A NDIR infrared detector for CO2 Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972E | N/A Paramagnetic sensor for O2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972F | N/A NDIR infrared detector for CH4 Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 972G | N/A NDIR infrared detector for CO2 Thermal conductivity cell for H2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 971A | N/A NDIR infrared detector for CO | N/A 0-2.0%, 0-50.0%, 0-100.0% CO | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 971B | N/A Thermal conductivity cell for H2 | N/A 0-2.0%, 0-50.0%, 0-100.0% H2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 971D | N/A NDIR infrared detector for CH4 | N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 971E | N/A NDIR infrared detector for CO2 | N/A 0-2.0%, 0-50.0%, 0-100.0% CO2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
| 971F | N/A Paramagnetic sensor for O2 | N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 | N/A 0.1% for all gases | N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |